Skip to content
ATEX/IECExFood GradeIP65/67NEMA 4X

BURKERT 20000614 Type 2100 Pneumatically Operated 2/2-Way Angle Seat Valve

Burkert 20000614 (Type 2100) pneumatically operated 2/2-way angle seat valve. Features stainless steel body, PTFE seal, weld end DN15, up to 25 bar and 185°C.

BURKERT 20000614 Type 2100 Pneumatically Operated 2/2-Way Angle Seat Valve

Burkert 20000614 (Type 2100) is a pneumatically operated 2/2-way angle seat valve specially optimised for decentralized process automation. It fulfils tough criteria in process environments, offering high flow rates and a long service life. Its unique design allows easy integration of automation units in all expansion stages, from electrical/optical position feedback to pneumatic control and integrated fieldbus interfaces. Maximum service life and tightness are achieved by the proven self-adjusting V-seal packing gland. The highly integrated system of valve and automation unit is characterised by its compact and smooth design, integrated pilot air ducts, protection classes IP65/67, NEMA Type 4X, and high resistance to chemicals.

Features

  • High flow rates
  • Long service life
  • Easy integration of automation units with ELEMENT
  • Flow-optimised stainless steel valve body with weld connection
  • Suitable for steam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, and organic solvents

Product Overview

Burkert 20000614 Type 2100 product overview diagram

  1. Transparent cap with position
  2. Actuator cover
  3. Actuator housing
  4. Relief bore
  5. Valve body
  6. Flow direction marking
  7. Port connection
  8. Body connection
  9. Actuator connection
  10. Pilot air port 1
  11. Pilot air port 2

Control Functions

Control function A (CF A)

Burkert 20000614 Type 2100 control function A symbol

Pneumatically operated 2/2-way on/off valve. Flow direction below seat. Normally closed by spring force.

Flow Direction Below the Seat

Burkert 20000614 Type 2100 flow direction below seat diagram

Only use flow direction below the seat for liquid media, gases, and vapours. As the medium is present under the swivel plate, the operating pressure contributes to the opening of the valve.

Water Hammer Hazard

Risk of damage due to bursting pipes and bursting equipment when the flow is above the seat. In the case of liquid mediums, water hammer can occur causing pipes and the device to burst. Do not use valves with flow above the seat for liquid mediums.

Material Specifications

Burkert 20000614 Type 2100 material specifications diagram

No.ElementMaterial
1Ground terminalStainless steel 1.4301/1.4305 (ATEX variant only)
2Optical position indicatorPolysulfone PSU
3Pilot air portsPush-in connector PP (Standard)
4Actuator coverPPS
5Actuator casingStainless steel 1.4561 (316Ti)
6Piston sealFKM
7SpringStainless steel 1.4310
8PipeStainless steel 1.4401 (316)/1.4404 (316L)
9Packing glandPTFE V-Rings (filled), with spring compensation
10SpindleStainless steel 1.4401 (316)/1.4404 (316L)
11Spindle guidePEEK
12Body sealGraphite, PTFE (Option)
13Swivel plateStainless steel 1.4401 (316)/1.4404 (316L)
14Seat sealPTFE, PEEK (Option)
15Valve bodyStainless steel CF3M

Lubricants

The lubricants for the packing gland and actuator are classified according to NSF H1.

Dimensions

Actuator

Burkert 20000614 Type 2100 actuator dimensions

Nominal diameter (DN)Actuator size ∅∅ A [mm]B [mm]H [mm]K/M [mm]
1550 (D)64.5166163147

Body with Welded Connection

Burkert 20000614 Type 2100 welded connection dimensions

Nominal diameter (DN)ES [mm]CS [mm]LS [mm]∅ DS [mm]WS [mm]
15 (ISO 4200 / DIN 11866 B)193410021.31.6

Operating Limits

Burkert 20000614 Type 2100 operating limits chart

In addition to the maximum operating pressures, the operating range of Burkert process valves is limited by the nominal pressure according to the relevant standard.

ATEX / Explosion Protection

For devices with ATEX/IECEx approval (e.g., EPS 18 ATEX 2 008 X II 2G Ex h IIC T4…T2 Gb / II 2D Ex h IIIC T135°C…T300°C Db), ensure proper grounding of the valve body and actuator. Do not open the spring-loaded actuator cover. Observe all specific conditions for safe use in potentially explosive atmospheres as detailed in the operating instructions.