BURKERT 20061169 Type 8652 AirLINE valve island optimised for process automation. Features 12 valve ports, büS/CANopen protocol, LC display diagnostics, and ATEX/IECEx Zone 2 approvals.

BURKERT 20061169 Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet. Moreover, key pneumatic functions ensure increased process reliability. For instance, check valves in the exhaust air ducts make sure there is no unplanned actuation due to pressure peaks.
This specific configuration (Article No. 20061169) features a 12-bank setup with büS/CANopen communication, D10 and D6 brass connections, and an AirLINE Quick aluminium adapter.

| Product properties | Description |
|---|---|
| Material | Body: PA (polyamide) Seal: NBR and PUR |
| Width per station | 11 mm |
| Manual override | Latching, spring return (optional: lockable) |
| Number of valve slots | Max. 24 |
| Maximum number of valve functions | Max. 48 |
| Pressure range | Vac...10 bar |
| External supply air (auxiliary pilot air) | 3...10 bar |
| Flow rate QNn value air | 310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure) |
| Operating voltage | 24 V DC (±10% tolerance) |
| Nominal power of each valve | 0.7 W (0.175 W after power reduction) |
| Nominal current of each valve | 29 mA (10 mA after power reduction) |
| Protection class | III according to DIN EN 61140, VDE 0140 |
| Operating medium | Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) |
| Degree of protection | IP20, IP65 in closed control cabinets |
| Ambient temperature | -10 °C...+55 °C |
AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.
Advantages:

| Circuit function | Description |
|---|---|
| C (CF C) | 3/2-way solenoid valve, servo-controlled, normally closed |
| D (CF D) | 2 × 3/2-way solenoid valve, servo-controlled, normally open |
| H (CF H) | 5/2-way solenoid valve, servo-controlled, pressure applied via port (1) |
| L (CF L) | 5/3-way solenoid valve, in middle position all ports locked |
| M (CF M) | 5/3-way solenoid valve, in middle position ports 2 and 4 ventilated |
| N (CF N) | 5/3-way solenoid valve, in middle position ports 2 and 4 exhausted |
| Z (CF Z) | 5/2-way solenoid valve, impulse variant with 2 coils |

INFO
Dimensions are in mm, unless otherwise stated. For full dimensional drawings of 16-, 20-, and 24-fold variants, please refer to the complete technical manual.

| Pin | Colour | Assignment |
|---|---|---|
| 1 | Red | 24 V DC |
| 2 | White | CAN_H (büS connection) |
| 3 | Green | SHIELDING |
| 4 | Blue | CAN_L (büS connection) |
| 5 | Black | GND |
TIP
CANopen requires 2 terminating resistors: one at the beginning of the network and one at the end. An indicator of the correct bus scheduling is the resistance between CAN_H and CAN_L when the power is switched off. This should be approx. 60 Ω.
The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.
Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).