Skip to content
Direct-actingUp to DN 2.5Vibration-proofIP65 / NEMA 4X

BURKERT 20142531 Type 6014 3/2-Way Direct-Acting Plunger Valve

Burkert Type 6014 (SKU 20142531) is a 3/2-way direct-acting plunger valve featuring a stainless steel body, NPT 1/4 connection, 24V DC, EPDM seal, and 0-10 bar pressure range.

BURKERT 20142531 Type 6014 3/2-Way Direct-Acting Plunger Valve

Burkert Type 6014 (SKU 20142531) is a direct-acting, compact 3/2-way plunger valve with a diameter of up to DN 2.5. The stopper and core guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. A Bürkert-specific flange variant (SFB) enables space-saving arrangement of valves on a manifold.

The valve features a vibration-proof, bolted coil system and offers options such as a banjo threaded connection for direct mounting on pneumatic valves, explosion-proof variants, and energy-saving variants with Kick and Drop coils for the reduction of electrical power consumption during operation.

General Technical Data

Product PropertiesDescription
OrificeDN 1.5...DN 2.5
Circuit functionC, D and T
Thermal insulation classPolyamide coil class B, Epoxy coil class H
Duty cycle100% continuous operation. Intermittent operation 60% (30 min) or with 5 W coil (on request)
Operating voltage24 V DC, 24 V 50 Hz, 24 V 60 Hz, 110 V 50 Hz, 120 V 60 Hz, 230 V 50 Hz, 240 V 60 Hz (other voltages on request)
Voltage tolerance±10%
Operating mediumTechnical vacuum, neutral gases and liquids (e.g. compressed air, town gas, natural gas, water, hydraulic oil, petrol)
ViscosityMax. 21 mm²/s
Installation positionAs required, preferably with actuator upright
Ambient temperatureMax. +55 °C

Circuit Functions

Circuit FunctionDescription
C (CF C)3/2-way solenoid valve, Direct-acting, Normally closed
D (CF D)3/2-way solenoid valve, Direct-acting, Normally open
T (CF T)3/2-way solenoid valve, Direct-acting, Flow direction optional, Normally closed

Approvals and Conformities

Conformity Notes

The approvals and conformities listed below must be stated when making enquiries. Not all available variants can be supplied with the below mentioned approvals or conformities. In accordance with the Declaration of Conformity, the product is compliant with the EU Directives.

  • Explosion Protection: Optional explosion protection according to category 2 (zone 1/21) and category 3 (zone 2/22) with ATEX and IECEx certifications.
  • North America (USA/Canada): Optional UL Listed, UL Recognized, CSA, and FM (Factory Mutual) approvals. Canadian Registration Number (CRN) available.
  • Drinking Water: Suitable for use in drinking water applications. Materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV).
  • Foods and Beverages/Hygiene: FDA (Code of Federal Regulations), USP (United States Pharmacopeial Convention), and EC Regulation 1935/2004 compliance available for specific variable codes.
  • Others: DNV GL classification for ships, offshore units, and high-speed craft. Fire protection on railway vehicles in accordance with DIN EN 45545.

Materials

BURKERT 20142531 Burkert Type 6014 material specifications for standard variant

Standard Variant Material Specifications:

No.ElementMaterial
1StopperStainless steel 1.4105/430F
2Shading ringCu (brass variant), Ag (stainless steel variant)
3Plunger sealFKM
4SpringStainless steel 1.4310/301
5Magnetic coreStainless steel 1.4105/430F
6Core guide tubeStainless steel 1.4303/305/308
7O-ringFKM
8Plunger sealFKM
9Valve bodyBrass, Stainless steel 1.4305/303, Stainless steel 1.4401/316
10SpringStainless steel 1.4310/301
11Sub-baseSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant)
12CoilPA (Polyamide), Epoxy (High temperature variant)
13NutSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant)

Dimensions

Note

All dimensions are in mm.

BURKERT 20142531 Burkert Type 6014 standard variant dimensions

BURKERT 20142531 Burkert Type 6014 standard variant dimensions side view

BURKERT 20142531 Burkert Type 6014 dimensions table

Performance Specifications

Power Consumption:

Orifice [mm]Coil power [W]Inrush AC [VA]Hold AC [VA/W]Opening [ms]Closing [ms]
1.58 W AC or 8 W DC (9)24810...1515...20
2.08 W AC or 8 W DC (9)24810...1515...20
2.58 W AC or 8 W DC (9)24815...2010...22

(Measurement at +20 °C, 6 bar at the valve outlet, opening: pressure build-up 0…90%, closing: pressure reduction 100…10%)

Utilisation in Another Circuit Function (Max. Operating Pressure [bar]):

DNCircuit functionABCDT
1.5C16221622
1.5D22.52162
1.5T10161066
2.0C10141011
2.0D11.51101
2.0T610644
2.5C6960.70.7
2.5D0.710.760.7
2.5T3.563.52.52.5

Product Installation

Control for impulse variant with polarity reversal control

  • Please use only the cable plug without electrical wiring for the impulse variant.
  • Pulse duration at least 50 ms.

Polarity (marked on the coil with a label):

  • - switch ON + : valve open ((+) on terminal 2 and (-) on terminal 1)
  • + switch OFF - : valve closed ((+) on terminal 1 and (-) on terminal 2)