BURKERT 20052011 Type 8745 Mass Flow Controller/Meter for CO2. Features 50 kg/h flow rate, 24 V DC supply, G 1/2" internal thread, and 4-20 mA signal.

BURKERT 20052011 Type 8745 Mass Flow Controller / Meter is designed for controlling the mass flow of large gas quantities, specifically configured for CO2 with a nominal flow rate of 50 kg/h. It features a 24 V DC supply voltage, G 1/2" internal thread port connection, and a 4-20 mA input/output signal. The Type 8745 can be configured as a Mass Flow Meter (MFM) or Mass Flow Controller (MFC). The thermal inline sensor located directly in the main gas stream achieves very fast response times with minimal pressure loss. As an actuator, a Bürkert direct-acting proportional valve guarantees high response sensitivity.

| Property | Description |
|---|---|
| Seal | FKM or EPDM (depending on gas) |
| Housing | PC (polycarbonate) |
| Base block | Aluminium or stainless steel 1.4404/316L |
| Wetted parts (sensor) | Stainless steel 1.4404/316L, Al2O3, PPS GF40, epoxy resin, silicon, silicon nitride |
| Operating voltage | 24 V DC (Residual ripple ±2%, Voltage tolerance ±10%) |
| Operating medium | Neutral, pure gases (CO2 carbon dioxide for this configuration) |
| Medium temperature | -10 °C to +70 °C (-10 °C to +60 °C with oxygen) |
| Analogue interface | 4...20 mA, 0...20 mA, 0...10 V or 0...5 V |
| Digital communication | Modbus RS-485/RTU, Industrial Ethernet: EtherCAT®, EtherNet/IP, Modbus TCP, PROFINET |
| Degree of protection | IP20 |
The MFC variant uses direct-acting proportional valves of the 287x series. These electromagnetic proportional valves are normally closed and stand for highest measuring accuracy and repeatability with settling times of a few hundred milliseconds.
| Performance Data | Specification |
|---|---|
| Nominal flow range (QN) | MFC: 20...1500 lN/min (N2) / MFM: ≤ 2500 lN/min (N2) |
| Operating pressure | MFM: max. 25 bar / MFC: max. 25 bar |
| Measuring accuracy | ±1.5% MV, ±0.3% FS |
| Repeatability | ±0.1% FS |
| Turndown ratio | 1:50 |
| Settling time (t95) | < 500 ms |
Type 8745 with electromotive proportional valve is especially suitable for applications with high inlet pressures of up to 22 bar or high flow rates (at a low pressure drop). The motor’s power consumption to hold a specific opening position is nearly zero.
| Performance Data | Specification |
|---|---|
| Nominal flow range (QN) | 20...2500 lN/min (N2) |
| Operating pressure | MFM: max. 22 bar |
| Measuring accuracy | ± 2% MV, ± 0.5% FS |
| Repeatability | ± 0.5% FS |
| Settling time (t95) | < 5 s |
| Conformity | Description |
|---|---|
| North America | Optional: UL Listed for the USA and Canada (UL 61010-1) |
| FDA | All wetted materials are compliant with the Code of Federal Regulations published by the FDA. |
| USP | All wetted materials are biocompatible according to the manufacturer's declaration. |
| EC 1935/2004 | All wetted materials are compliant with EC Regulation 1935/2004/EC. |
| Oxygen | Optional: Suitability for oxygen. |
Small nominal flow rates, with internal thread

| Thread (A) | Thread depth [mm] |
|---|---|
| G 1/4 | 12 |
| NPT 1/4 | 11 |
| G 3/8 | 12 |
| NPT 3/8 | 11 |
| G 1/2 | 15 |
| NPT 1/2 | 14 |
| G 3/4 | 16 |
| NPT 3/4 | 15 |
Industrial Ethernet (Terminal strip, 3-pin)
| Pin | Assignment |
|---|---|
| 1 | FE (functional earth) |
| 2 | DGND |
| 3 | 24 V |
Analogue (Terminal strip, 6-pin)
| Pin | Assignment |
|---|---|
| 1 | 24 V |
| 2 | GND |
| 3 | Set-point value input + |
| 4 | Set-point value input GND |
| 5 | Actual value output + |
| 6 | Actual value output GND |
Modbus RTU (D-Sub plug, 9-pin)
| Pin | Assignment |
|---|---|
| 2 | GND |
| 3 | 24 V |
| 6 | RS-485-Y |
| 7 | RS-485-Z |
| 8 | RS-485-B |
| 9 | RS-485-A |
| Housing | Shielding |
MFM Pressure Loss Diagram

Nominal Flow Rate of Typical Gases
| Gas | Min. QN [l/min] | Max. QN [l/min] |
|---|---|---|
| Acetylene | 20 | 320 |
| Ammonia | 8 | 1000 |
| Argon | 20 | 1600 |
| Carbon dioxide | 20 | 800 (1000 in some variants) |
| Air | 20 | 2500 |
| Methane | 20 | 1200 |
| Propane | 20 | 200 |
| Oxygen | 20 | 2500 |
| Nitrogen | 20 | 2500 |
Derating Diagram for Electromotive Variants

Measurement Principle
This sensor works as a hot-film anemometer in the so-called CTA operational mode (Constant Temperature Anemometer). Two resistors with a precisely specified temperature coefficient located directly in the media flow and three further resistors are connected to form a measuring bridge. The heating current required to maintain a fixed excess temperature is a measure of the heat dissipation and represents the primary measured variable.

Electrostatically sensitive components
The device contains electronic components that are susceptible to the effects of electrostatic discharging (ESD). Do not touch electronic components when the supply voltage is connected.
Electric shock hazard
Touching live parts can result in severe electric shock. Before working on the device or system, switch off the power supply and secure it against reactivation.
Medium under pressure
Medium under pressure can seriously injure people. Before working on the device or system, switch off the pressure and vent or empty the lines.