BURKERT 20088850 Type 8640 Modular Valve Island for Pneumatics

BURKERT Type 8640 modular valve island (SKU 20088850). Features 33mm add-on dimension, G 1/2 pressure port, 2-8 bar pressure range, and DIN-rail mounting.

BURKERT 20088850 Type 8640 Modular Valve Island for Pneumatics

BURKERT Type 8640 modular valve island system is designed to solve diverse and complex control problems due to its systematic modular construction and combination of pneumatic and electrical interfaces. By putting together a row of pneumatic modules with different numbers of valves, 2 to 24 valve functionalities may be realized on one valve unit. Electrical connectivity is achieved by either fieldbus interfaces, common connection (parallel connection technique) or multipin interfaces. The valves allow different applications to be covered. Bodies and connection modules are made of high-quality plastic (polyamide) and are easy to assemble by means of the built-in snap connectors.

BURKERT 20088850 BURKERT Type 8640 modular valve island overview

Key advantages of the Type 8640 system include its compact design, modular configuration, and higher flexibility in the control cabinet due to AirLINE Quick compatibility. It allows for the simple exchange of valves, which is also possible during operation when equipped with the "P-shut-off" option.

General Technical Data

The Type 8640 valve island can be equipped with various pilot valves (such as Type 0460, 6524, 6525, 6526, 6527, and 5470) to suit different application requirements.

Product PropertiesType 0460, 6524, 6525Type 6526, 6527Type 5470
Body MaterialPA (polyamide), aluminium (Type 0460)PA (polyamide), aluminiumPA (polyamide)
Seal MaterialFKM, NBR and PURNBRNBR
Width per station11 mm16.5 mm19 mm
Manual overrideStandardStandardStandard
Number of valve slotsMax. 24 (Max. 12 for impulse/double valves)Max. 24Max. 24
Pressure rangeVac...10 barVac...10 barVac. 2...10 bar
Nominal operating modeContinuous operation (100% duty cycle)Continuous operation (100% duty cycle)Continuous operation (100% duty cycle)
Operating voltage24 V DC (±10% tolerance)24 V DC (±10% tolerance)24 V DC (±10% tolerance)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Degree of protectionIP20 (IP65 in closed control cabinets)IP20 (IP65 in closed control cabinets)IP20 (IP65 in closed control cabinets)

Product Design and Assembly

Installing Multiple Blocks

BURKERT 20088850 BURKERT Type 8640 example of a multi-block

  1. Begin installation with the connection module on the left.
  2. Check modules for complete installation with 2 O-rings each.
  3. Lightly oil or grease all O-rings before engaging.
  4. Engage the lower latch hooks of the module to be attached in the latch grooves of the preceding module. Make sure that the O-rings are properly seated.
  5. Press the module to be locked upwards slightly and engage the upper latch hook.
  6. Insert 3 O-rings into the recess on the back of the valve and ensure that the seal is properly fitted.

WARNING

Crushed O-rings and profile seals lead to leaky blocks. Fasten each valve to the base module with 2 screws. Recommended tightening torque is 0.6 ±0.1 Nm.

Valve Block Installation

BURKERT 20088850 BURKERT Type 8640 mounting the valve block

Standard rail installation:

  • Hook the valve block with the upper groove into the standard rail (35 x 15 or 35 x 7.5 EN 50022).
  • Snap the lower clamping pieces into the standard rail.
  • Tighten the screws on the clamping pieces.

Wall installation:

  • Fasten the valve block directly to the wall with M4 screws.

Tightening Torques for Port Connections

Observe the following tightening torques when screwing into the port connections. The specified tightening torque may vary depending on the sealing system.

Port sizeMarking/functionRecommended tightening torque [Nm]Maximum tightening torque [Nm]
G1/4, NPT1/4P, R/S connection4...720
G1/8, NPT1/8P, R/S connection A/B valve outlets3...67

Maintenance and Troubleshooting

FaultPossible causeRemedy
Valves do not switchNo operating voltage or operating voltage too lowCheck electrical connection. Ensure operating voltage according to type label.
Manual override not in zero positionBring manual override to zero position.
Pressure supply insufficient or not availableSet up large-volume pressure supply. Minimum operating pressure ≥ 2 bar.
Valves switch with a delay or blow off at the exhaust portsPressure supply insufficient or not availableSet up large-volume pressure supply. Minimum operating pressure ≥ 2 bar.
Valves are not in the home position (de-energised) during pressure build-upApply pressure to the valve block before the valves are switched.
Insufficient ventilation of the exhaust air ducts due to too small or dirty silencersUse suitably sized silencers or expansion vessels. Clean the dirty silencers.
Impurities or foreign matter in the pilot or pneumatic valveApply pulsed pressure to the exhaust air ducts to blow out the impurities. Install a new pilot or pneumatic valve.
Leaky valve blocksMissing or crushed O-rings between the modulesIdentify leak or missing seals.
Missing or incorrectly positioned flat seals between valve and base plateInsert missing seals or replace damaged seals.