BURKERT Type 2301 pneumatically operated 2-way globe control valve. Features a flow-optimized stainless steel body, PTFE/PEEK seals, and high cycle life for process environments.

BURKERT Type 2301 pneumatically operated 2-way globe control valve fulfils tough criteria for process environments. Unrivalled cycle life and sealing integrity is guaranteed by the proven self-adjusting spindle packing with exchangeable V-seals. Each globe valve body can be fitted with up to five sizes of trim sets. These parabolic trims provide a reliable and repeatable characteristic to vary the flow. The control cones are available in either stainless steel or with a durable PTFE seal or PEEK seal for tight shut-off. Leakage class III, IV or VI are available. The design enables the easy integration of automation modules whether they are digital electropneumatic positioners or process controllers. The fully integrated system has a compact and smooth design, integrated pneumatic lines, IP65/67 protection class and superior chemical resistance.

| Product properties | Specification |
|---|---|
| Design | Globe control valve |
| Nominal diameter (port connection) | DN 10...DN 100, NPS 3/8...NPS 4 |
| Safety setting in case of power failure | Normally closed (control function A), normally open (control function B) |
| Flow direction | Flow to open (below seat) |
| Operating pressure | 0...25 bar(g), 40 bar(g) on request. Vacuum variant...- 0.9 bar(g) (option) |
| Nominal pressure | PN 25/PN 40 (DIN EN 1333), Class 150 (DIN EN 1759) |
| Seat leakage | Leakage class III and IV (DIN EN 60534 - 4:2006) for stainless steel. Leakage class VI for PTFE and PEEK |
| Operating characteristic | Equal percentage, linear (others on request) |
| Theoretical rangeability | 50:1 |
| Medium | Steam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, organic solvents, oxygen and fuel gases, Hydrogen (optional), Iyes (optional) |
| Medium temperature | - 40 °C...+ 230 °C |
| Viscosity | Max. 600 mm2/s |
| Control medium | Air, neutral gases |
| Ambient temperature | - 10...+ 80 °C (with positioner Type 8791/8792/8793), - 10...+ 55 °C (with positioner Type 8692/8693/8694) |
| Degree of protection | IP65/67 |
| Installation position | As required, preferably with actuator upright |

| No. | Element | Material |
|---|---|---|
| 1 | Pilot air ports | Push-in connector PP |
| 2 | Actuator cover | PPS |
| 3 | Actuator casing | Stainless steel 1.4561 (316Ti) |
| 4 | Piston seal | FKM |
| 5 | Spring | Stainless steel 1.4310 |
| 6 | Pipe | Stainless steel CF3M |
| 7 | Packing gland | PTFE V-Rings (filled), with spring compensation |
| 8 | Spindle | Stainless steel 1.4401 (316)/1.4404 (316L) |
| 9 | Spindle guide | Stainless steel 1.4404 (316L), PTFE filled |
| 10 | Body seal | Graphite or PTFE |
| 11 | Control cone | Stainless steel 1.4571 (optionally hardened) |
| 12 | Spring straight pin | Stainless steel 1.4310 |
| 13 | Seat seal | Stainless steel 1.4571 (optionally hardened), PTFE or PEEK |
| 14 | Valve seat with o-Ring | Stainless steel 1.4571, EPDM |
| 15 | Valve body | Stainless steel 316L / CF3M |

Optional Variants
Depending on the variant, the valve is closed against the medium flow either with spring force (CFA) or pilot pressure (CFB and CFI). Because the medium pressure is below the control cone, it helps open the valve.

WARNING
Valve leak if there is too little minimum pilot pressure or high medium pressure! Minimum pilot pressure for CFB and CFI that is too low, or failing to meet the permitted medium pressure, can cause a leak in the valve seat. Adhere to minimum pilot pressure and do not exceed the medium pressure.
DANGER
Risk of injury when opening the actuator! The actuator contains a spring under tension. When the actuator is opened, the spring will jump out and may cause injuries. Do not open the actuator.