TLV SS1-M2 series stainless steel free float steam trap for steam mains and tracer lines. Features three-point seating and a thermostatic air vent for fast start-up.

The TLV SS1-M2 series free float steam trap uses a precision-ground float and three-point support for the valve body. With no hinges or levers, the trap automatically and continuously discharges condensate, preventing it from collecting. This stainless steel steam trap is ideal for places at which extremely small amounts of condensate are generated, such as superheated and saturated steam mains and branches, and trace lines.
At start-up, before steam is supplied, the system is cold and the bimetal air vent strip is contracted, holding the float off of the valve seat. This allows for the rapid discharge of air and cold condensate through the valve when steam is first supplied to the system.

If the temperature of the condensate rises above 90 °C, the bimetal air vent strip expands allowing the float to block the valve seat. Rising condensate levels cause the float to rise due to buoyancy, opening the valve and allowing hot condensate to be discharged.

When the condensate flow rate decreases, the float falls, closing off the valve seat opening. A water seal is maintained at all times over the valve seat opening to prevent steam loss.

WARNING
Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. DO NOT use this product in excess of the maximum operating pressure differential. Such use could make discharge impossible (blocked).
| Model | Installation | Connection | Max Operating Temp (°C) |
|---|---|---|---|
| SS1NL-M2 | Horizontal | Screwed, Socket Welded, Flanged | 220 |
| SS1VL-M2 | Vertical | Screwed, Socket Welded, Flanged | 220 |
| SS1NH-M2 | Horizontal | Screwed, Socket Welded, Flanged | 400 |
| SS1VH-M2 | Vertical | Screwed, Socket Welded, Flanged | 400 |
DANGER
NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment.
WARNING
Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids.
SS1NL-M2 / SS1NH-M2 (Horizontal Installation Model)
SS1VL-M2 / SS1VH-M2 (Vertical Installation Model)
A visual inspection of the following items should be done on a daily basis: